Description
MAGUS Bio V300 is a biological microscope with an inverted design for examining samples in laboratory vessels up to 70 mm high and with bottom thickness up to 1.2 mm. The objects under study can be cell colonies, tissue cultures, biological fluids, etc. Samples do not necessarily require prior staining. Observations are made in transmitted light. Microscopy methods: brightfield and phase contrast. The microscope is suitable for daily and research work, and for teaching.
Digital camera
Video eyepiece with a digital SONY Exmor 8.3 MP sensor. The sensor uses back-illumination technology to improve light sensitivity and produce bright, clear images even in low light. The camera is used for darkfield and brightfield methods with 4x, 10x and 20x objectives. It can also work with stereomicroscopes. A USB 3.0 port with high data transfer speed (5 Gbps) is used to connect to a computer and display images on the screen.
The MAGUS CDF30 camera is mounted in the trinocular tube or in the eyepiece tube of the microscope. The maximum field of view without optical defects can be achieved with an adapter with magnification from 0.65x to 0.9x. To mount it in an eyepiece tube, you will also need, in addition to the adapter, an adapter ring matching the diameter of the tube.
The image is displayed on the computer screen with a maximum resolution of 3840x2160 px. The frame rate is 45 fps. At a lower resolution (1920x1080 px) the frame rate increases to 70 fps. Transitions between frames are almost imperceptible, without delays, and therefore the camera can be used to study and demonstrate moving objects. Photos and videos are taken and saved in various formats.
Optics
The microscope is equipped with a classic trinocular head, and the trinocular tube is used to mount a digital camera. The camera is not included in the kit. Beam splitting is 50/50.
The four objectives supplied with the kit, or additional objectives, can be mounted in the nosepiece. All objectives are designed for use with laboratory vessels and have a long working distance. There are 3 planachromatic objectives for brightfield microscopy and 1 planachromatic objective for phase contrast observations.
Illumination
The transmitted light source is a 9 W LED. The high power of the LED makes the illumination of the working area bright enough to work with all objectives and with any microscopy method. Adjusting the brightness does not change the colour temperature. The service life of the LED is 50,000 hours without replacement.
The condenser has a slider slot for phase contrast observation (included in the kit). Phase contrast rings can be centred. Mounting the slider saves time when changing the observation method.
Stage and focusing mechanism
Fixed mechanical stage. It is equipped with a vessel holder (three vessel holders of different sizes are supplied). The vessels can be moved along the X and Y axes by a mechanical device. The coaxial coarse and fine focusing mechanism provides precise and fast focusing. Coarse focusing has a locking mechanism and tension adjustment.
Accessories
The group of additional accessories includes phase contrast objectives, eyepieces, digital cameras and calibration samples.
Main characteristics of the microscope:
- Brightfield and phase contrast observation in transmitted light, examination of samples in laboratory vessels
- A digital camera is mounted in the trinocular tube
- 9 W LED transmitted light illuminator with adjustable brightness and long service life
- Fixed stage with movement along two axes; 3 vessel holders of different sizes are included in the kit
- Additional accessories to improve the working characteristics of the microscope
Main characteristics of the camera:
- Colour CMOS SONY Exmor sensor with back-illumination, high light sensitivity
- Operation with darkfield and brightfield methods with 4x, 10x and 20x objectives
- Connection to a computer via a USB 3.0 interface with 5 Gbps data transfer speed
- Image output to a monitor with ultra-high resolution 4K 3840x2160 px (45 fps) or Full HD 1920x1080 px (70 fps)
- Drivers and image processing software are included
- Mounting in the trinocular tube or in the eyepiece tube of the microscope
The kit includes:
- MAGUS CDF30 digital camera (digital camera, USB cable, installation CDs with drivers and software, user manual and warranty card)
- Stand with built-in power supply, transmitted light source, focusing mechanism, stage, condenser with slot for phase contrast attachment, and nosepiece
- Trinocular head
- Planachromatic objective with infinity correction: PL 10x/0.25 WD 4.3 mm
- Planachromatic objective with infinity correction: PL L20x/0.40 WD 8.0 mm
- Planachromatic objective with infinity correction: PL L40x/0.60 WD: 3.5 mm
- Planachromatic objective with infinity correction: PHP2 10x/0.25 phase contrast WD 4.3 mm
- Eyepiece 10x/22 mm with wide eye relief (2 pcs.)
- Eyepiece caps (2 pcs.)
- Centring telescope
- Phase contrast slider with phase centring rings
- Mechanical device for moving samples
- Vessel holder (3 pcs.)
- Camera adapter with C-mount
- Colour filter
- AC power cable
- Dust cover
- User manual and warranty card
Available on request:
- Eyepiece 10x/22 mm with scale
- Eyepiece 12.5x/14 mm (2 pcs.)
- Eyepiece 15x/15 mm (2 pcs.)
- Eyepiece 20x/12 mm (2 pcs.)
- Eyepiece 25x/9 mm (2 pcs.)
- Planachromatic objective with infinity correction: PL 4x/0.10 WD 21 mm
- Planachromatic objective with infinity correction: PHP2 20x/0.40 phase contrast WD 8.0 mm
- Planachromatic objective with infinity correction: PHP2 40x/0.60 phase contrast WD 3.5 mm
- Calibration sample
- Monitor and digital camera with HDMI interface
Specifications
| Warranty | 5 years |
|---|---|
| Package dimensions (L x W x H) | 64x42x67 cm |
| Shipping weight | 18.6 kg |
| Type | biological, light/optical, digital |
| Microscope head type | trinocular |
| Head | Siedentopf |
| Head inclination angle | 45° |
| Magnification, x | 100 — 400 |
| Magnification range | from 200x to 800x |
| Magnification, x (option) | 40–500/600/800/1000 |
| Eyepiece tube diameter, mm | 30 |
| Eyepieces | 10x/22 mm, eye relief: 10 mm (*option: 10x/22 mm with scale, 12.5x/14; 15x/15; 20x/12; 25x/9) |
| Objectives | planachromatic infinity-corrected: PL 10x/0.25; PL 20x/0.40; PL 40x/0.60; PHP2 10x/0.25 phase contrast; parfocal distance: 45 mm (*option: PL 4x/0.10; PHP2 20x/0.40 phase contrast; PHP2 40x/0.60 phase contrast) |
| Revolving nosepiece | for 4 objectives |
| Working distance, mm | 21.0 (4x); 4.3 (10x); 8.0 (20x); 3.5 (40x) |
| Interpupillary distance, mm | 48 — 75 |
| Stage movement range, mm | 77/112 |
| Stage characteristics | fixed with mechanical specimen manipulation device, vessel holders: 29x77 mm, Ø90 mm; 34x77.5 mm, Ø68.5 mm; 57x82 mm, Ø60 mm |
| Condenser | NA 0.6, working distance: 70 mm; with adjustable aperture diaphragm and slot for phase contrast slider |
| Diaphragm | adjustable aperture |
| Focusing | coaxial, coarse (with coarse focus tension adjustment and locking button) and fine (0.002 mm) |
| Body | solid aluminium |
| Illumination | LED |
| Brightness adjustment | yes |
| Power supply | 220±22 V, 50 Hz, AC mains |
| Light source type | 9 W |
| Light filters | yes |
| Operating temperature range, °C | 5 — 35 |
| Special features | phase contrast slider, for 10x objective with centrable phase contrast ring |
| User level | for professionals, experienced users |
| Assembly difficulty level | complex |
| Application | laboratory/medical |
| Illumination position | top (transmitted light) |
| Examination method | bright field, phase contrast microscopy |
| Bag/case/pouch included | dust cover |
| Sensor | SONY Exmor CMOS |
| Colour/monochrome | colour |
| Megapixels | 8.3 |
| Maximum resolution, pixels | 3840x2160 |
| Sensor size | 1/1.2'' (11,14x6,26 mm) |
| Pixel size, μm | 2.9x2.9 |
| Light sensitivity | 5970 mV/lux/s |
| Signal-to-noise ratio | 0.13 mV at 1/30 s |
| Exposure time | 0.02 ms – 15 s |
| Video recording | yes, yes |
| Frame rate, fps at resolution | 45 at 3840x2160, 70 at 1920x1080 |
| Mounting location | trinocular tube, eyepiece tube instead of eyepiece |
| Image format | *.jpg, *.bmp, *.png, *.tif |
| Video format | output: *.wmv, *.avi, *.h264 (Windows 8 and newer), *h265 (Windows 10 and newer) |
| Spectral range, nm | 380–650 (built-in infrared filter) |
| Shutter type | ERS (electronic rolling shutter) |
| White balance | automatic, manual |
| Exposure control | automatic, manual |
| Software features | exposure time, image size, brightness |
| Software | MAGUS View |
| Output | 5 Gb/s, USB 3.0 |
| System requirements | Windows 8/10/11 (32-bit and 64-bit), Mac OS X, Linux, up to 2.8 GHz Intel Core 2 or more powerful, at least 2 GB RAM, USB 3.0 port, CD-ROM, 17" or larger display |
| Mount type | C-mount |
| Camera power supply | DC, 5 V, from USB port of computer; adapter for 12 V, 3 A for powering the Peltier element |
| Camera operating temperature range, °C | -10 — 50 |
| Operating humidity range, % | 30 — 80 |