Description
The Ermenrich Zing TC20 digital multimeter is a portable device for measuring DC/AC voltage, DC/AC current, resistance and capacitance. It has no rotary switch, i.e. the measuring range is set automatically. Overload-protected, the device is reliable and stable, and provides high measurement accuracy. It is most suitable for those interested in radio communications, DIY enthusiasts and professional electricians.
In wire-mapping mode it checks circuit continuity – the device locates breaks or short circuits. The diode test is used to check diodes by measuring the voltage drop across them. The device uses the true RMS method, which means that measurements are made based on the true RMS formula, which improves the accuracy of results when measuring AC voltage and AC current. It has additional functions such as data hold, non-contact voltage detection (NCV) and a flashlight.
The device is powered by two standard batteries (not included).
Key features:
- No rotary dial, measuring range is set automatically
- Measurement of DC/AC voltage, DC/AC current, resistance, capacitance
- Wire-mapping mode, diode testing, non-contact voltage detection
- True RMS method improves accuracy when measuring AC voltage and AC current
The set includes:
- Digital multimeter
- Probes – 2 pcs.
- User manual and warranty card
Specifications
| Warranty | 5 years |
|---|---|
| Packaging size (L x W x H) | 16x10x5 cm |
| Shipping weight | 0.32 kg |
| Measuring range selection | automatic |
| Basic functions | ammeter, voltmeter, capacitance meter, ohmmeter |
| DC voltage measuring range | 0.6–1000 V |
| DC voltage measurement limit | 1000 V: error ±(0.8%+10), resolution 1 V, 6/60/600 V: error ±(0.5%+3), resolution 0.001/0.01/0.1 V |
| AC voltage measuring range | 0.6–750 V |
| AC voltage measurement limit | 6/60/600 V: error ±(0.5%+3), resolution 0.001/0.01/0.1 V, 750V: error ±(0.8%+10), resolution 1 V |
| DC current measuring range | 20 mA–10 A |
| DC current measurement limit | 6/10 A: error ±(2.0%+30), resolution 0.001/0.01 A |
| AC current measuring range | 20 mA – 10 A |
| AC current measurement limit | 6/10 A: error ±(2.0%+30), resolution 0.001/0.01 A |
| Resistance measuring range | 0.1 Ohm – 60 MOhm |
| Resistance measurement limit | 6 kOhm/60 kOhm/600 kOhm/6 MOhm: error ±(0.8%+3), resolution 1 Ohm/10 Ohm/100 Ohm/1 kOhm, 60 MOhm: error ±(2.5%+3), resolution 10 kOhm, 600 Ohm: error ±(0.8%+5), resolution 0.1 Ohm |
| Capacitance measuring range | 10 nF – 60 mF |
| Capacitance measurement limit | 10 nF/100 nF/1 µF/10 µF/100 µF/1 mF/10 mF: error ±(3.5%+20), resolution 10 pF/100 pF/1 nF/10 nF/100 nF/1 µF/10 µF, 60 mF: error ±(5%+3), resolution 100 µF |
| Measurements per second | 3 |
| Wire mapping | yes |
| Circuit continuity test | + |
| Diode test | yes |
| Diode check | + |
| Non-contact voltage detection (NCV) | yes |
| Data hold function | yes |
| Display | Liquid crystal display |
| Number of display units | 5999 |
| Display digits | 3 5/6 |
| Display backlight | yes |
| Flashlight | yes |
| Overvoltage category | cat. IV |
| Operating temperature range, °C | 0 — 40 |
| Power supply | 2 AAA batteries (not included) |
| "Low battery" status indicator | yes |
| Automatic power off | yes |