Description
The Ermenrich Ping ET60 earth resistance tester is a device designed to measure earth ground resistance in the range from 0 to 4 kΩ. It has a built-in screen with an LCD display, three test leads of different lengths and two earth stakes. The device runs on batteries, has an auto power-off function, and notifies you when the batteries need replacing if their charge is insufficient. It is recommended that measurements and equipment diagnostics be carried out with a high battery charge level; otherwise the results may not be reliable.
The device stores measurements in memory, records maximum, minimum and average values, and performs relative measurements against a reference value. The "Data Hold" function is designed to "freeze" measurement results on the device screen in situations where you need them later.
The Ermenrich Ping ET60 is a measuring instrument used for checking power distribution lines, designing lightning protection systems, diagnosing high-voltage poles, buildings, communication stations, internal cable connections, electrical equipment, etc. It has high measuring accuracy and is suitable for professional use.
Key features:
- Earth resistance measurement using the direct current conversion method
- Earth voltage measurement using the digital rectified average method
- Memory for 100 measurement groups, as well as for storing minimum, maximum and average values
- Display hold function for measurement results, calculation based on reference values
- Powered by standard batteries, auto power-off function and low battery warning
The kit includes:
- Earth loop resistance tester
- Test leads – 3 pcs.
- Additional earth stakes – 2 pcs.
- Case
- User manual and warranty card
Specifications
| Warranty | 5 years |
|---|---|
| Package dimensions (L x W x H) | 33x27x9 cm |
| Shipping weight | 2.315 kg |
| Earth resistance measurement range | 0–29.99 Ω: error (±2%+6), resolution 0.01 Ω; 30–99.9 Ω: error (±3%+3), resolution 0.1 Ω; 100–999 Ω: error (±3%+3), resolution 1 Ω; 1.00–4.00 kΩ: error (±3%+3), resolution 10 Ω |
| Earth potential | 0 V–200 V (50–60 Hz): accuracy (±1%+5), resolution 0.1 V |
| Measurement method | two-wire, three-wire |
| Earth loop resistance measurement parameters | test current 3 mA, 800 Hz |
| Memory | 100 groups |
| Average value memory (AVG) | yes |
| Relative value measurement (REL) | yes |
| Display | yes |
| Display backlight | yes |
| Graphic scale | yes |
| Safety standards | EN61010-1, EN61557-3, EN61326-1 |
| Overvoltage category | cat. III (1000 V), cat. IV (600 V) |
| Data storage/read function | yes |
| "Data Hold" function | yes |
| Limit value memory (Min./Max.) | yes |
| Power supply | 8 AA batteries (not included) |
| "Low battery" status indicator | yes |
| Automatic power-off | yes |